EMC

EN 55032 / CISPR 32 Conducted emission (Class B)

EN 55032 / CISPR 32 Class B conducted emission.

Conducted Class B dBµV

Limit curve (log scale)

Frequency range Limit Unit Detector
150.00 kHz - 500.00 kHz 66 dBµV QP
150.00 kHz - 500.00 kHz 56 dBµV AV
500.00 kHz - 5 MHz 56 dBµV QP
500.00 kHz - 5 MHz 46 dBµV AV
5 MHz - 30 MHz 60 dBµV QP
5 MHz - 30 MHz 50 dBµV AV

Data sourced from industry standards, for engineering reference only. Consult official publications for compliance and certification.